Physical layer: cables, fiber, Ethernet and the NIC

The Physical layer (Layer 1) turns a frame's bits into real signals: voltage on copper, light on fiber, radio on Wi-Fi. Cable type, distance limits, the NIC, speed and duplex all live here, and most "link down" or "slow link" problems start here.

4.1 What Layer 1 does

  • The frame is just ones and zeros; Layer 1 converts the bits into a signal and puts it on the medium.
  • Copper: electrical voltage. Fiber: light pulses. Wi-Fi: radio waves.
  • Layer 1 only cares about bits and signals, not MAC or IP.
PC to server over Cat6 copper
  1. 1.PC 192.168.24.10: NIC turns the frame into bits 10110010

  2. 2.Bits travel as voltage on the Cat6 cable

  3. 3.Switch receives the signal and forwards it

  4. 4.Server 192.168.24.20: NIC turns the signal back into bits

On fiber the same bits are light pulses, on Wi-Fi radio waves

4.2 Twisted pair copper cable

  • 8 wires twisted into 4 pairs; the twist cancels noise (EMI) and crosstalk.
  • UTP (Unshielded Twisted Pair) is the normal cable; STP adds foil shielding for noisy places like factories.
  • One copper run can be at most 100 meters; after that the signal fades.
  • RJ45 connector: 8 pins, one wire per pin in a fixed color order (T568A or T568B; offices mostly use T568B).
  • Auto MDI-X on modern NICs adjusts the pairs automatically, so PC-to-PC crossover cables are no longer needed.

4.3 Categories: Cat5e, Cat6, Cat6a

CategorySpeedDistanceBandwidth
Cat5e1 Gbps100 m100 MHz
Cat61 Gbps (10 Gbps up to ~55 m)100 m250 MHz
Cat6a10 Gbps100 m500 MHz
  • Cat5e is today's minimum; Cat6a is used in new offices and data centers for full 10 Gbps at 100 m.

4.4 Beyond 100 m: repeater or fiber

  • Two buildings 300 m apart: a direct copper run gets so weak that the Building B switch cannot understand it.
  • Repeater (Layer 1): regenerates the weak signal at full strength and sends it on; it ignores MAC and IP.
  • Fiber: bits travel as light pulses in a thin glass core; the better solution for distance.
Fiber from the data center to another city
  1. 1.Server in the data center

  2. 2.Multi mode fiber to the core switch (~300-550 m)

  3. 3.Core switch to the Delhi router

  4. 4.Single mode fiber, Delhi router to Noida router (40 km)

  5. 5.Light pulses arrive, the receiver turns them back into bits

4.5 Comparison: single mode vs multi mode fiber

PointMulti mode (MMF)Single mode (SMF)
Core size~50 µm~9 µm
LightBounces along many pathsLaser, one straight path
Distance300-550 m (about 400 m at 10 Gbps)10-80+ km
CostCheaperCostlier optics
Used forInside a data center / buildingISP and long links between cities

4.6 NIC, speed, duplex and autonegotiation

  • NIC (Network Interface Card): converts the frame into a signal and the signal back into bits.
  • Autonegotiation: when the cable is plugged in, the NIC and switch port exchange the speeds/duplex they support and pick the highest common one (e.g. 1 Gbps full).
  • Half duplex: one side talks at a time, like a walkie-talkie (hubs, Wi-Fi).
  • Full duplex: both sides send and receive together, like a phone call; twisted pair has separate pairs for each direction.
  • Duplex mismatch: one side full, the other half: errors and a slow link.
Autonegotiation
  1. 1.Cable plugged in: PC NIC and switch port 1 detect the link

  2. 2.NIC sends: I can 10/100/1000 Full

  3. 3.Switch replies: me too, 1000 Full

  4. 4.Both pick the highest common mode

  5. 5.Link up: 1 Gbps Full on both ends

4.7 Hub and repeater: Layer 1 devices

  • Hub: repeats bits from one port out of every other port; PC A's data for PC B is also seen by PC C and PC D (wasted bandwidth, security risk).
  • All hub ports share one medium, so a hub runs half duplex.
  • If PC B and PC D send together, the signals collide; both follow CSMA/CD, wait a random time and retry.
  • More devices on a hub = more collisions = slower. A switch has full duplex ports, so no collisions.
DeviceLayerWhat it does
Repeater1Regenerates a weak signal
Hub1Repeats bits out of all ports, half duplex, collisions
Switch2Forwards by MAC to one port, full duplex, no collisions

4.8 Practical: speed and duplex with ethtool

Docker LAN: PC 192.168.24.10, server 192.168.24.20. ethtool is the Linux tool for NIC details.

Terminal
ethtool eth0ethtool -i eth0ethtool -s eth0 speed 1000 \  duplex full autoneg offip link set eth0 downethtool eth0 | grep Linkip link set eth0 upethtool eth0 | grep Linkping -c 2 192.168.24.20
Output
$ ethtool eth0Settings for eth0:    Speed: 10000Mb/s    Duplex: Full    Auto-negotiation: off    Port: Twisted Pair    Link detected: yes$ ethtool -i eth0driver: vethversion: 1.0supports-statistics: yes
  • Speed 10000Mb/s (10 Gbps), Duplex Full, Link detected: yes.
  • driver: veth = Docker's virtual NIC; it reports a fixed speed with autonegotiation off.
Output
$ ethtool -s eth0 speed 1000 duplex full autoneg offnetlink error: Not supported$ ip link set eth0 down$ ethtool eth0 | grep Link    Link detected: no$ ip link set eth0 up$ ethtool eth0 | grep Link    Link detected: yes$ ping -c 2 192.168.24.2064 bytes from 192.168.24.20: icmp_seq=1 ttl=64 time=6.96 ms64 bytes from 192.168.24.20: icmp_seq=2 ttl=64 time=0.122 ms
  • Forcing 1 Gbps full gives Not supported: a virtual NIC has no physical chip.
  • On a real server ethtool -s fixes the speed, but both ends must then have the same setting.
  • ip link set eth0 down -> Link detected: no (like unplugging the cable); up -> yes, and ping works again.

4.9 Practical: Get-NetAdapter on Windows

PowerShell
Get-NetAdapter -Name "Ethernet","Wi-Fi" |  Select-Object Name, Status, LinkSpeed,  FullDuplex | Format-Table -AutoSize$p = Get-NetAdapterAdvancedProperty -Name `  "Ethernet" -DisplayName "Speed & Duplex"$p.DisplayValue$p.ValidDisplayValues
Output
Name     Status       LinkSpeed FullDuplex----     ------       --------- ----------Ethernet Disconnected 0 bpsWi-Fi    Up           150 Mbps  False$ $p.DisplayValueAuto Negotiation$ $p.ValidDisplayValuesAuto Negotiation10 Mbps Half Duplex10 Mbps Full Duplex100 Mbps Half Duplex100 Mbps Full Duplex1.0 Gbps Full Duplex
  • Ethernet: Disconnected, 0 bps (no cable plugged in).
  • Wi-Fi: Up at 150 Mbps, FullDuplex False: Wi-Fi is a shared radio medium, half duplex.
  • Speed & Duplex is on Auto Negotiation; the other values are fixed speed/duplex options.
  • Get-NetAdapter only reads, it changes nothing.

4.10 Common mistakes

  • Myth: a Cat6 cable makes your internet faster. The slowest link decides the speed; on a 100 Mbps plan you get 100 Mbps with Cat5e or Cat6.
  • A better cable matters only when you need more than 1 Gbps inside the LAN.
  • Running copper beyond 100 m.
  • Forcing speed/duplex on one end only: causes a duplex mismatch.
  • 800 m at 10 Gbps: not copper (100 m), not multi mode (~400 m); choose single mode fiber.

4.11 Interview tips

  • Half vs full duplex: half = one side at a time (hub, Wi-Fi), collisions and CSMA/CD; full = both together, no collisions, 2x bandwidth.
  • Mention duplex mismatch for bonus points: one side full, one half, errors and slow link.
  • Cat5e/Cat6 = 1 Gbps, Cat6a = 10 Gbps, copper max 100 m.
  • MMF for short runs (hundreds of meters), SMF for kilometers.
  • Hub and repeater are Layer 1; switch is Layer 2.